Residential calculation

Residential Load Calculator

A five-step estimate based on the supplied Load Calculation workbook. Enter actual equipment nameplate values before reviewing your service capacity.

01 General lighting & circuits

Floor area × 3 VA + small-appliance circuits × 1,500 VA + laundry circuits × 1,500 VA

Step 1 total: 10,500 VA

02 Heating & cooling

This workbook estimate adds the entered HVAC rows at 100%. Include each physical unit once. Actual NEC 220.82(C) calculations select the applicable heating/cooling demand.

EquipmentQuantityVA per unitFactorTotal VA
A/C Heat up to 8 kW1×0
A/C Heat up to 15 kW1×0
A/C Heat up to 20 kW1×0
Cond/Heat Pump to 2 T1×0
Cond/Heat Pump to 4 T1×0
Cond/Heat Pump to 5 T1×0
Other Electric Heating Device1×0
Step 2 total: 0 VA

03 Dedicated equipment

Quantities start at zero. Suggested VA values come from the workbook; replace them with actual labels. Enter each appliance in only one section.

EquipmentQuantityVA per unitFactorTotal VA
Electric Water Heater1×0
Refrigerator1×0
Freezer1×0
Dishwasher1×0
Disposal1×0
Range Hood1×0
Microwave1×0
Well pump1×0
Jacuzzi1×0
Pool Lights1×0
EVSE (continuous load)1.25×0
EVSE (continuous load)1.25×0
Step 3 total: 0 VA

04 Major equipment

Quantities start at zero. Suggested VA values come from the workbook; replace them with actual labels. Enter each appliance in only one section.

EquipmentQuantityVA per unitFactorTotal VA
Cook Range1×0
Cook Oven1×0
Clothes Dryer1×0
Water Heater1×0
Hot Tub1×0
Pool Light1×0
Pool Heater1×0
Step 4 total: 0 VA

Heat pump water heater

Use this row only if the same equipment is not already included above.

05 Service capacity estimate

General load: steps 1 + 3 + 4 + heat pump water heater
10,500 VA
First 10,000 VA at 100%
10,000 VA
Remaining general load at 40%
200 VA
Heating / cooling at 100%
0 VA
Total adjusted worksheet load
10,200 VA
42.5 A10,200 VA ÷ 240 V

Within the entered service rating on this estimate
157.5 A remaining.

Method: reproduces the supplied workbook’s arithmetic, including EVSE × 125% inside the general-load demand tier. This is not a verified NEC service design or a determination that a panel upgrade is required. Review method eligibility, HVAC selection, EVSE treatment, service conductors, and local requirements separately. Reference for optional dwelling calculations: 2023 NEC 220.82; EV equipment: 220.57 and 625.42. The worksheet assumes 240 V and does not calculate conductor or breaker sizes.

Print on Letter paper at 100% scale with browser headers and footers turned off. Name and address appear on the report.

ELECTRICAL HELPS

Residential Load Calculator

Prepared for: ____________________
Property: ________________________________________

Floor area: 2,000 ft²Small-appliance circuits: 2Laundry circuits: 1

General lighting & circuits: (2,000 × 3) + (2 × 1,500) + (1 × 1,500) = 10,500 VA

Group / equipmentQtyVA / unitFactorTotal VA
Heating & cooling0
A/C Heat up to 8 kW07,6001×0
A/C Heat up to 15 kW012,0001×0
A/C Heat up to 20 kW022,4001×0
Cond/Heat Pump to 2 T02,5001×0
Cond/Heat Pump to 4 T05,5001×0
Cond/Heat Pump to 5 T07,0001×0
Other Electric Heating Device04,8001×0
Dedicated equipment0
Electric Water Heater04,5001×0
Refrigerator01,4001×0
Freezer06001×0
Dishwasher01,2001×0
Disposal08001×0
Range Hood06001×0
Microwave01,5001×0
Well pump09001×0
Jacuzzi01,2001×0
Pool Lights08001×0
EVSE013,4401.25×0
EVSE09,6001.25×0
Major equipment0
Cook Range08,0001×0
Cook Oven05,0001×0
Clothes Dryer05,0001×0
Water Heater04,5001×0
Hot Tub04,5001×0
Pool Light03001×0
Pool Heater01,5001×0
Heat pump water heater001×0

Demand calculation

General load (lighting, circuits & equipment)
10,500 VA
First 10,000 VA at 100%
10,000 VA
Remaining general load at 40%
200 VA
Heating / cooling at 100%
0 VA
Adjusted worksheet total
10,200 VA

Service comparison

42.5 A
10,200 VA ÷ 240 V

Entered service: 200 A
120/240 V, single phase

157.5 A remaining
Worksheet estimate only