2023 NEC · 25 questions

Master practice exam

25 questions: 15 calculations and 10 challenging code questions based on the 2023 NEC.

Answered 0 of 25
Your time runs from opening this exam until submitting it, including breaks. Reloading starts a new attempt.
01 [Calculation] A 4,000 ft² office uses a 1.3 VA/ft² general-lighting unit load. What is its general-lighting load before any other loads?
02 [Calculation] A commercial lighting circuit has 16 A of continuous load. What minimum branch-circuit conductor ampacity is required before adjustment factors?
03 [Calculation] A 45 kVA, three-phase transformer has a 480 V primary. Approximately what is the primary full-load current?
04 [Calculation] A 25 kVA single-phase transformer has a 240 V primary. Approximately what is the primary full-load current?
05 [Calculation] A continuous-duty motor has a table full-load current of 28 A. What is the minimum single-motor branch-circuit conductor ampacity?
06 [Calculation] A feeder supplies two motors with table currents of 28 A and 14 A. What minimum feeder ampacity does the basic motor rule yield?
07 [Calculation] For a three-phase squirrel-cage motor (other than a Design B energy-efficient motor) with a 28 A table full-load current, what is 250% for an inverse-time circuit breaker under the table value rule?
08 [Calculation] A single dwelling electric clothes dryer is nameplate-rated 4,500 W. What load is used under the 2023 NEC dryer minimum?
09 [Calculation] A single dwelling electric clothes dryer is rated 6,000 W. What load is used before any multi-dryer demand factor?
10 [Calculation] Under Table 220.55 Column C, what is the demand for one 12 kW household range?
11 [Calculation] Under Table 220.55 Column C, what is the demand for two 12 kW household ranges?
12 [Calculation] A box has six 12 AWG insulated conductor allowances and one 12 AWG device yoke (two allowances). Ignoring all other fill, what volume is required?
13 [Calculation] A raceway has 0.533 in² internal area and contains more than two conductors. What is its maximum general fill area?
14 [Calculation] A 120 V, 1,800 W resistive load draws what current?
15 [Calculation] A 2,400 ft² dwelling is assigned 3 VA/ft² of general lighting load for this exercise. What is the undemanded lighting load?
16 [Code] A feeder is installed as parallel sets in separate metal raceways, with a wire-type equipment grounding conductor in each raceway. How is each equipment grounding conductor generally sized?
17 [Code] A pull box contains conductors 4 AWG and larger arranged as an angle pull. Which rule determines the distance from a raceway entry to the opposite wall?
18 [Code] A four-wire, three-phase wye circuit supplies mostly nonlinear loads. How is its neutral treated for conductor ampacity adjustment?
19 [Code] Which installation is excluded from the next-higher standard overcurrent device allowance in 240.4(B)?
20 [Code] A 25-foot feeder tap qualifies under 240.21(B)(2). Which combination is required?
21 [Code] For a continuous-duty motor over 1 hp with a marked service factor of 1.15, a separate overload device is initially selected using which value?
22 [Code] Which proposed parallel phase-conductor installation fails the matching requirements, even if both conductors have adequate ampacity?
23 [Code] Emergency conductors share an enclosure with normal wiring at transfer equipment. Is the general separation rule alone enough to reject the installation?
24 [Code] A grounding electrode conductor is spliced in a wireway. Which splice method is permitted by the general continuity rule?
25 [Code] A conductor has 90°C insulation, but equipment terminals are rated 75°C. Which statement describes use of the 90°C ampacity column?